|
Vector Laboratories
undigested pcr product Undigested Pcr Product, supplied by Vector Laboratories, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/undigested+pcr+product/DNA/us11421004-2533-1-10 Average 99 stars, based on 1 article reviews
undigested pcr product - by Bioz Stars,
2026-11
99/100 stars
|
Buy from Supplier |
|
Qiagen
undigested pcr product Undigested Pcr Product, supplied by Qiagen, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/undigested+pcr+product/QIAquick+PCR+Purification+Kit/pm30778069-328-21-28 Average 99 stars, based on 1 article reviews
undigested pcr product - by Bioz Stars,
2026-11
99/100 stars
|
Buy from Supplier |
|
Illumina Inc
gel-purified out-out1 pcr products (undigested band or untreated) ![]() Gel Purified Out Out1 Pcr Products (Undigested Band Or Untreated), supplied by Illumina Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/undigested+pcr+product/gel+purified+out+out1+pcr+products++undigested+band+or+untreated+/pmc04756813-53-1-1 Average 90 stars, based on 1 article reviews
gel-purified out-out1 pcr products (undigested band or untreated) - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Neurona Therapeutics
undigested pcr product (s. neurona) ![]() Undigested Pcr Product (S. Neurona), supplied by Neurona Therapeutics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/undigested+pcr+product/undigested+pcr+product++s++neurona+/10__2307_slash_3285623-162-0-4 Average 90 stars, based on 1 article reviews
undigested pcr product (s. neurona) - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
Journal: Nucleic Acids Research
Article Title: Highly efficient homology-driven genome editing in human T cells by combining zinc-finger nuclease mRNA and AAV6 donor delivery
doi: 10.1093/nar/gkv1121
Figure Lengend Snippet: Combination of ZFN mRNA and AAV6 vectors promotes high levels of gene correction-like events at the CCR5 locus in CD8 + T cells. ( A ) Schematic showing use of AAV vector as a template for homology directed repair (HDR) of a double-strand break (DSB), as induced by target-specific nucleases, to introduce a corrected gene sequence or transgene into a predetermined genomic target site. ( B ) Schematic of AAV vector genomes containing CCR5 -RFLP homology donors. L (left) and R (right) refer to CCR5 genomic sequences, comprising 509 and 1349 bp respectively. ( C ) CD8 + T cells were transduced with AAV6 vectors carrying the CCR5 -RFLP donor at indicated doses for 16 hours, then electroporated with CCR5 ZFN mRNA (60μg/ml). Cells were analyzed 7 days post-electroporation by deep sequencing to measure the efficiency of genome modification (% indels and RFLP). Combined results of three experiments using three different CD8 + T cell donors are shown. Mean ± SD. * P < 0.05, two-tailed t -test to compare %RFLP between conditions with different doses of AAV6 donor in the presence of ZFN mRNA treatment. ( D ) Dose-dependent insertion of XhoI site at CCR5 , confirmed by RFLP analysis. Adjusted%RFLP HDR are shown below the lanes with visible RFLP bands based on deep sequencing results of the undigested top band due to incomplete digestion. The %RFLP before adjustment are shown in parentheses. One representative experiment is shown.
Article Snippet: For
Techniques: Plasmid Preparation, Introduce, Sequencing, Genomic Sequencing, Transduction, Electroporation, Modification, Two Tailed Test
Journal: Nucleic Acids Research
Article Title: Highly efficient homology-driven genome editing in human T cells by combining zinc-finger nuclease mRNA and AAV6 donor delivery
doi: 10.1093/nar/gkv1121
Figure Lengend Snippet: Combination of ZFN mRNA and AAV6 vectors promotes high levels of transgene addition at the CCR5 locus in CD8 + T cells. ( A ) Schematic of AAV vector genomes containing CCR5 -GFP homology donors. L (left) and R (right) refer to CCR5 genomic sequences, comprising 476 and 1428 bp, respectively. ( B ) CD8 + T cells were treated as described in Figure , but using CCR5 -GFP donor vectors, with and without CCR5 ZFN mRNA electroporation. Cells were collected at 14 days post-transduction and analyzed by flow cytometry for %GFP + , and by deep sequencing to measure% indels. Results were combined from three experiments using three different CD8+ T cell donors. Mean ± SD. * P < 0.05, two-tailed t -test to compare%GFP + between conditions with different doses of AAV6 donor in the presence of ZFN mRNA treatment. ( C ) Flow cytometry plots from one representative experiment were shown using 1 × 10 6 vg/cell CCR5 -GFP donor, at 14 days post-electroporation. ( D ) Confirmation of targeted integration of GFP expression cassette at the CCR5 locus by semi-quantitative PCR. The %GFP HDR was estimated by comparison to standards.
Article Snippet: For
Techniques: Plasmid Preparation, Genomic Sequencing, Electroporation, Transduction, Flow Cytometry, Sequencing, Two Tailed Test, Expressing, Real-time Polymerase Chain Reaction, Comparison
Journal: Nucleic Acids Research
Article Title: Highly efficient homology-driven genome editing in human T cells by combining zinc-finger nuclease mRNA and AAV6 donor delivery
doi: 10.1093/nar/gkv1121
Figure Lengend Snippet: AAV6 vectors and ZFN mRNA promote high levels of gene correction-like events at the AAVS1 locus in CD8 + T cells. ( A ) Schematics of AAV6 vectors used to deliver AAVS1 homology donors. L (left) and R (right) refer to AAVS1 genomic sequences, comprising 789 and 837 bp respectively . ( B ) CD8 + T cells were transduced with AAV6 vectors carrying the AAVS1 -RFLP donor at indicated doses (vg/cell) for 16 h and/or electroporated with AAVS1 ZFN mRNA. Cells were analyzed 7 days post-electroporation by Illumina deep sequencing to measure the efficiency of genome modification (% indels and RFLP). Results are combined from three experiments using three different CD8 + T cell donors. Mean ± SD. * P < 0.05, two-tailed t -test to compare%RFLP between conditions with different doses of AAV6 donor in the presence of ZFN mRNA treatment. ( C ) Confirmation of insertion of HindIII site at the AAVS1 locus by RFLP assay. Adjusted%RFLP HDR are shown below the lanes with visible RFLP bands based on deep sequencing results of the undigested top band due to incomplete digestion. The %RFLP before adjustment are shown in parentheses. One representative experiment is shown.
Article Snippet: For
Techniques: Genomic Sequencing, Transduction, Electroporation, Sequencing, Modification, Two Tailed Test, RFLP Assay
Journal: Nucleic Acids Research
Article Title: Highly efficient homology-driven genome editing in human T cells by combining zinc-finger nuclease mRNA and AAV6 donor delivery
doi: 10.1093/nar/gkv1121
Figure Lengend Snippet: AAV6 vectors and ZFN mRNA promote high levels of transgene addition at the AAVS1 locus in CD8 + T cells. ( A ) Schematics of AAV6 vectors used to deliver AAVS1 -GFP homology donors. L (left) and R (right) refer to AAVS1 genomic sequences, comprising 789 and 570 bp, respectively. ( B ) CD8 + T cells were treated as described in Figure , but using AAVS1 -GFP donor. Cells were collected 14 days post-transduction and analyzed by flow cytometry for %GFP + , and by deep sequencing to measure% indels. Results were combined from three experiments using three different CD8 + T cell donors. Mean ± SD. * P < 0.05, two-tailed t -test to compare %GFP + between conditions with different doses of AAV6 donor in the presence of ZFN mRNA treatment. ( C ) Flow cytometry plots from a representative experiment using 1 × 10 6 vg/cell AAVS1 -GFP donor at 14 days post-electroporation.
Article Snippet: For
Techniques: Genomic Sequencing, Transduction, Flow Cytometry, Sequencing, Two Tailed Test, Electroporation